What was found
L/H IB FLAP VANE L/E PN:601R14303-53 AT WS 50.498+6.0"" HAS CHAFE DAMAGE MEASURING 1.30"L X .650"W X .020"D. EVALUATED DAMAGE AND FOUND NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 57-52-00 REV 39. *********AIRCRAFT REMOVED FROM SERVICE*************************** VERIFIED A SMOOTH BLEND WITH REMAINING THICKNESS OF .030" WITH ORIGINAL THICKNESS OF .050" 2024-T3 IAW ASAP EA AWAC-CRJ257-01873 REV A DATED 08/23/2022. HFEC INSPECTION ACCOMPLISHED AT BLEND AREA WITH NO INDICATIONS IAW CRJ200 NDT MANUAL PART 1 51-20-06 REV 43. ENSURED AERODYNAMIC SMOOTHNESS AT BLEND AREA IAW CRJ200 SRM 51-21-16 REV 39. RESTORED PROTECTIVE/DECORATIVE FINISH AT BLEND AREA IAW CRJ200 SRM 51-21-16 REV 39. ALL WORK PERFORMED WITHIN ALLOWABLE LIMITS IAW ASAP EA #AWAC-CRJ257-01873 REV A DATED 08/23/2022. WORK COMPLETED ON AERSALE WO #003697 CARD #20130 CARD ID #1699163 AT AERSALE CRS #4AER685B N457AW TT: 39,910:44 TC: 39,007