What was found
CORROSION ON SERVICE DOOR FLOOR ANGLE P/N: 601R38303-253 BENEATH FITTINGS AT FS 329 AND FS 342 AND RBL 42 - RBL 45. *******************AIRCRAFT REMOVED FROM SERVICE********************* BLENDED TWO EACH AREAS ON SERVICE DOOR FLOOR ANGLE P/N: 601R38303-253 WITH DIMENSIONS: (P1) FS 325-330 = 5.0"L X 1.9"W X .025"D AND (P2) FS 339-343 = 5.0"L X 1.9"W X .033"D IAW CRJ200 SRM 53-00-00 REV 39 AND CRJ200 SRM 51-21-06 REV 39. BLEND AREAS AT (P1) AND (P2) ARE NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 53- 00-00 REV 39. ORIGINAL MATERIAL THICKNESS OF FLOOR ANGLE P/N: 601R38303-253 IS .063". REMOVED SERVICE DOOR FLOOR ANGLE AT FS 319 TO FS 349 RBL 42 - RBL 46 IAW CRJ200 SRM 51-42-06 REV 39. LOCATED AND DRILLED NEW SERVICE DOOR FLOOR ANGLE AT FS 319 TO FS 349 RBL 42 - RBL 46 IAW CRJ200 DRAWING PL601R38303 AND CRJ200 SRM 51-41-02 REV 39. INSTALLED NEW SERVICE DOOR FLOOR ANGLE P/N: 601R38303-253 IAW CRJ200 SRM 51-42-06 REV 39, CRJ200 SRM 51-42-13 REV 39, AND CRJ200 SRM 51-42-20 REV 39. WORK ACCOMPLISHED ON AERSALE WO #003697 CARD #20169 AT AERSALE CRS#4AER685B. N457AW TT: 39,910:44 TC: 39,007