Service difficulty report · Stiffener · Cndair CL6002B19

Difficulty date
January 22, 2025
Submitted
January 28, 2025
Operation
Air carrier
Aircraft
N444ZW
Make and model
Cndair CL6002B19
Aircraft serial
7788
Aircraft time
41,998 hours, 41,166 cycles
Part
Stiffener
Condition
Melted
Location
Zone 100
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

REQUEST INSPECTION FOR SHORTED GROUND POWER RECEPTACLE. AC GROUND POWER AIRCRAFT REMOVED FROM SERVICE. INSPECTED AND FND A/C RECEPT AND SHIELD MELTED, RECEPT SUPPORT MEMBER & INTERCOSTAL HAS HEAT DAMAGE AND MELTED AREAS. FWD PRESS BULHEAD HAS APPROX 2"X 1.5" HOLE IN IT WITH SURROUNDING AREA METAL DISCOLORED, WARPED AND CRACKING. BLKHD VERT STIFFNER AND NLG BAY WEB HAVE SPARKING DAMAGE SIMILAR TO LIGHTNING STRIKE. RIVETS AT FS199 FOR RECEPT INTERCOSTAL HAVE BEGUN TO MELT, BUT ARE NOT NOT LOOSE. REF 370607-3 FOR OPS CK OF AC PWR GEN SYSTEMS REF 370607-1FOR ORIG DISCREPANCY