What was found
TUL - INBOARD OF STR 18R BELOW FLOOR STA 1287 - STA 1309, WEB ON FLOOR PAN CRACKED AND CORRODED SEVERAL PLACES. REF: E58-4A NR 0140524. INSTALLED NEW CUSP SECTION FROM STA 1250R TO STA 1309R (SRM 51-01) PAR 1.C. INSTALLED DOUBLERS, 2 EACH, AT THROTTLE CABLE LIGHTNING HOLES (AARD 53-00-00-02). REINSTALLED NR 5 AND NR 6 SEAT TRACKS STA 250 - STA 1309R. TST: 44,359.42 HOURS. CYCLES: 24,074. (X)