What was found
ATL - FLT 1572 - DURING APPROACH, SLAT/FLAP HANDLE MOVED TO ZERO DEGREE/EXTERNAL. DISAGREE LIGHT CAME ON. RECYCLED HANDLE AND BOTH SLATS AND LIGHTS NORMAL. LANDED ATL WITHOUT INCIDENT. DURING REFUELING OPERATION, PERSON FUELING NOTICED SPARKS COMING FROM A WIRE BUNDLE OUTBOARD OF FUELING PANEL. REFUEL DOOR HODL OPEN ROD SHORTING SLAT/FLAP WIRES BUNDLE. REPAIRED AND REPOSITIONED BURNED WIRES IN BUNDLE AT REFUEL DOOR. SYSTEM GROUND CHECK NORMAL OPERATION. (M)