What was found
DFW - FLT 1183 - DURING TAXI, MASK COMPARTMENT AT SEAT 7AB OPENED AND OXYGEN GENERATOR FIRED. RETURNED TO GATE. REMOVED AND REPLACED SEAT 7AB OXYGEN GENERATOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DFW - FLT 1183 - DURING TAXI, MASK COMPARTMENT AT SEAT 7AB OPENED AND OXYGEN GENERATOR FIRED. RETURNED TO GATE. REMOVED AND REPLACED SEAT 7AB OXYGEN GENERATOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)