What was found
TUL - FOUND FLOORBEAM HAS DAMAGE AT STATION 218 AND RBL 13 HAS CUT MARK. BLENDED DAMAGED AREA, INSTALLED DOUBLER PER SRM 53-05 PART 1 FIG 20A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND FLOORBEAM HAS DAMAGE AT STATION 218 AND RBL 13 HAS CUT MARK. BLENDED DAMAGED AREA, INSTALLED DOUBLER PER SRM 53-05 PART 1 FIG 20A. (M)