What was found
HNL - FLT 102 - AFTER TAKEOFF AT FIRST POWER REDUCTION NR 2 EGT WENT FULL OFF SCALE. OVERTEMP LIGHT ILLUMINATED, N1-N2 NORMAL. REPLACED NR 2 THERMOCOUPLE LEAD. ENGINE RUN ACCOMPLISHED. SYSTEM GROUND CHECK NORMAL OPERATION. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HNL - FLT 102 - AFTER TAKEOFF AT FIRST POWER REDUCTION NR 2 EGT WENT FULL OFF SCALE. OVERTEMP LIGHT ILLUMINATED, N1-N2 NORMAL. REPLACED NR 2 THERMOCOUPLE LEAD. ENGINE RUN ACCOMPLISHED. SYSTEM GROUND CHECK NORMAL OPERATION. (M)