What was found
TUL - FOUND CORROSION ON FLOOR/GALLEY SUPPORT FROM FRAME 74.5 TO 80 RIGHT SUPPORT . REPLACED SECTION OF FLOOR/GALLEY SUPPORT BEAM FROM FRAME 74.5 TO FRAME 80 IAW SRM 51-77-10-0. (M)