What was found
MIA DURING OVERNIGHT MAINTENANCE R1 DOOR EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED R1 DOOR EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEMS GROUND CHECKED NORMAL OPERATION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MIA DURING OVERNIGHT MAINTENANCE R1 DOOR EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED R1 DOOR EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEMS GROUND CHECKED NORMAL OPERATION.