What was found
TUL - FOUND CORROSION, 6 INCHES BY 16 INCHES AND .030 DEEP, ON BOTTOM SIDE OF SUB FLOOR AT FORWARD SERVICE DOOR STATION 170 RBL 56. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-01 FIG 4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION, 6 INCHES BY 16 INCHES AND .030 DEEP, ON BOTTOM SIDE OF SUB FLOOR AT FORWARD SERVICE DOOR STATION 170 RBL 56. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-01 FIG 4. (M)