What was found
TUL - FOUND STRINGER 22L FLANGE DAMAGED AT STATION 1174 AND CORROSION 2 INCHES BY 7 INCHES, IN STRINGER ON FILLER AT STATION 1180. REMOVED DAMAGED AREA OF STRINGER. INSTALLED STRINGER SPLICE PER SRM 53-10-3. INSTALLED NEW FILLER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STRINGER 22L FLANGE DAMAGED AT STATION 1174 AND CORROSION 2 INCHES BY 7 INCHES, IN STRINGER ON FILLER AT STATION 1180. REMOVED DAMAGED AREA OF STRINGER. INSTALLED STRINGER SPLICE PER SRM 53-10-3. INSTALLED NEW FILLER. (M)