What was found
TUL - FOUND 11 SPOTS OF CORROSION IN LEFT AFT LAVATORY FLOOR FROM LBL 30 INCHES TO LBL 50 INCHES. REMOVED CORROSION PER SRM 51-10-00. INSTALLED REPAIR DOUBLER OVER OUT OF LIMITS PORTION PER SRM 51-40-00. TREATED AND PRIMED AREA. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND 11 SPOTS OF CORROSION IN LEFT AFT LAVATORY FLOOR FROM LBL 30 INCHES TO LBL 50 INCHES. REMOVED CORROSION PER SRM 51-10-00. INSTALLED REPAIR DOUBLER OVER OUT OF LIMITS PORTION PER SRM 51-40-00. TREATED AND PRIMED AREA. (M)