What was found
TUL - FOUND AFT CARGO COMPT LATERIAL FLOOR SUPPORT BEAM CORRODED THROUGH AT FRAME 60 BETWEEN ROLLER TRAYS NR 1 AND NR 2. CUT OUT CORRODED SECTION OF FLOOR SUPPORT BEAM AND SPLICED IN NEW SECTION PER SRM 53-1015. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND AFT CARGO COMPT LATERIAL FLOOR SUPPORT BEAM CORRODED THROUGH AT FRAME 60 BETWEEN ROLLER TRAYS NR 1 AND NR 2. CUT OUT CORRODED SECTION OF FLOOR SUPPORT BEAM AND SPLICED IN NEW SECTION PER SRM 53-1015. (M)