As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT LBL 33, STATION 791 HAD CORROSION BLENDED BEYOND SRM LIMITS. REMOVE CORROSION PER REF /D/. VERIFY CRACK FREE ROTOPEEN, APPLY ALODINE AND TWO COATS PRIMER TO BLENDED AREA. FILL BLENDED AREA WITH BMS5-95. RETURN TO SERVICE WITH NOTED CONDITION. (M)