As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FLOORBEAM AT RBL 11, STATION 798 HAD CORROSION BLENDED ON TOP SURFACE BEYOND SRM LIMITS. REMOVE CORROSION PER REF /D/ AND ENSURE CORROSION HAS BEEN COMPLETELY REMOVED. ROTO PEEN, APPLY ALODINE AND 2 COATS PRIMER TO BLEND AREA. FILL BLENDED AREA WITH BMS5-95. RETURN TO SERVICE WITH NOTED CONDITION. (M)