What was found
AFW - FUSELAGE STRAP AT STATION 1825 JUST BELOW 53R HAD INTERGRANNULAR CORROSION AT 2 NUT PLATES. REMOVED CORROSION PER REF/01. FABRICATE REPAIR DOUBLER FROM .125 INCH 7075-T6. FABRICATE FILLER AND SHIM FROM 7075-T6 THICKNESS AS REQUIRED. FINISH DOUBLER FILLER AND SHIM PER REF/D/. INSTALL REPAIR PARTS WET WITH BMS5-95 SEALANT, REFER TO FIGURE. USE BACB30NW6 HI-LOCKS OR EQUIVALENT. (M)