What was found
AFW - FOUND LOWER MAIN SILL NR 2 CX DOOR CUTOUT INNER CHORD HAS CORROSION REMOVAL AS SHOWN ON SKETCH. MATERIAL REMAINING IS 002 INCH BEYOND SRM LIMITS. REQUEST ENG APPROVAL TO CONT IN SERVICE. REMOVED CORROSION PER REF/C/. VERIFY CORROSION COMPLETELY REMOVED. APPLY ALODINE AND 2 COATS PRIMER TO BLEND AREAS. FILL BLENDS ON UPPER SURFACE W/BMS-95. APPLY CORROSION INHIBITING COMPOUND TO ENTIRE SILL AREA. (M)