What was found
TUL - CORROSION FROM STR 49L TO STR 50L AT FRAME 36. ALODINED, PRIMED, AND PAINTED PER SRM 51-74-10. INSTALLED NEW SHEARTIE PER SRM 51-72-10. TST: 32,241 HOURS. CYCLES: 12,979. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CORROSION FROM STR 49L TO STR 50L AT FRAME 36. ALODINED, PRIMED, AND PAINTED PER SRM 51-74-10. INSTALLED NEW SHEARTIE PER SRM 51-72-10. TST: 32,241 HOURS. CYCLES: 12,979. (X)