What was found
TUL - FOUND CORROSION ON CUSP SHEET UNDER AFT GALLEY AREA AT STATION 1307 LEFT. INSTALLED NEW CUSP SHEET UNDER AFT GALLEY STATION 1307 TO STATION 1183 LEFT IAW SRM 53-01 FIG 4 SHEET 3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION ON CUSP SHEET UNDER AFT GALLEY AREA AT STATION 1307 LEFT. INSTALLED NEW CUSP SHEET UNDER AFT GALLEY STATION 1307 TO STATION 1183 LEFT IAW SRM 53-01 FIG 4 SHEET 3. (M)