What was found
TUL - FOUND STATION 1130 FLOORBEAM HAS CORROSION ON TOP FLANGE AT APPROX LBL 25-LBL 10. FABRICATED STRAP TREATED AND PRIMED AND INSTALLED PER SRM 53-10-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND STATION 1130 FLOORBEAM HAS CORROSION ON TOP FLANGE AT APPROX LBL 25-LBL 10. FABRICATED STRAP TREATED AND PRIMED AND INSTALLED PER SRM 53-10-07. (M)