What was found
TUL - FOUND 2 INCH BY 32 INCHES OF CORROSION ON FLOORBOARD SUPPORT AT STATION 200, RBL 10-42. REMOVED AND REPLACED FLOORBOARD SUPPORT PER MM 51-00-00-8. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND 2 INCH BY 32 INCHES OF CORROSION ON FLOORBOARD SUPPORT AT STATION 200, RBL 10-42. REMOVED AND REPLACED FLOORBOARD SUPPORT PER MM 51-00-00-8. (M)