What was found
TUL - FOUND FUSELAGE SKIN CRACKED AND CORRODED STATION 1130 AT STRINGER 29R. CUT OUT 2 INCH BY 3 INCH AREA OF SKIN AND INSTALLED DOUBLER REPAIR PER SRM 53-30-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND FUSELAGE SKIN CRACKED AND CORRODED STATION 1130 AT STRINGER 29R. CUT OUT 2 INCH BY 3 INCH AREA OF SKIN AND INSTALLED DOUBLER REPAIR PER SRM 53-30-3. (M)