DFW - DURING OVERNIGHT MAINTENANCE, FOUND EMERGENCY EXIT CEILING LIGHTS STATION 1133 TO 1209 INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY EXIT CEILING LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)