What was found
TUL - FOUND LIGHT CORROSION AROUND FLAPPER DRAIN BETWEEN 28R AND BLO STATION 685. INSTALLED DOUBLER PER SRM 53-30-3 050 7075 T-6 9 INCH BY 9 INCH FOUR ROWS EACH SIDE .1875 RIVETS. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND LIGHT CORROSION AROUND FLAPPER DRAIN BETWEEN 28R AND BLO STATION 685. INSTALLED DOUBLER PER SRM 53-30-3 050 7075 T-6 9 INCH BY 9 INCH FOUR ROWS EACH SIDE .1875 RIVETS. (M)