What was found
AFW - FOUND RIGHT INBOARD FLAP OUTBOARD SUPPORT FITTING OUTBOARD TOP MOUNT BEARING LOOSE. REMOVED GOUGES AND REAM BORE TO 1.81-1.84 INCH DIAMETER. FABRICATE REPAIR BUSHING PER REF REPAIR 5-1 WITH THE FOLLOWING DEVIATIONS. BUSHING WALL THICKNESS TO BE A MINIMUM OF 0.30, SHANK .255 INCH. OMIT PENETRANT INSPECTION PRIOR TO NICKEL STRIKE/CAD PLATE. REAM BUSHING TO 1.750 INCH DIAMETER AFTER INSTALLATION. (M)