What was found
TUL - FOUND CORROSION ON UPPER ANGLE AFT SIDE OF FLOORBEAM STATION 160 RBL 12. INSTALLED FLOORBEAM TEE CAP REPAIR ON TOP SIDE OF FLOORBEAM STATION 160 FROM RBL 1 TO RBL 18 PER 53-05 FIG 20B SHEET 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND CORROSION ON UPPER ANGLE AFT SIDE OF FLOORBEAM STATION 160 RBL 12. INSTALLED FLOORBEAM TEE CAP REPAIR ON TOP SIDE OF FLOORBEAM STATION 160 FROM RBL 1 TO RBL 18 PER 53-05 FIG 20B SHEET 2. (M)