What was found
TUL - FOUND LEFT AFT CABIN FLOOR CUSP CRACKED BETWEEN LIGHTENING HOLES, INBOARD OF PREVENTIVE DOUBLER, STATION 1300. ROUTED-OUT DAMAGED SECTION OF CUSP. INSTALLED INTERIM REPAIR FILLER AND DOUBLER PER ESO 80559. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND LEFT AFT CABIN FLOOR CUSP CRACKED BETWEEN LIGHTENING HOLES, INBOARD OF PREVENTIVE DOUBLER, STATION 1300. ROUTED-OUT DAMAGED SECTION OF CUSP. INSTALLED INTERIM REPAIR FILLER AND DOUBLER PER ESO 80559. (M)