Service difficulty report · Controller · Boeing 757223

Difficulty date
April 26, 2002
Submitted
July 11, 2002
Operation
Air carrier
Aircraft
N656AA
Make and model
Boeing 757223
Aircraft serial
24614
Part
Controller
Condition
Failed
Location
E/E Bay
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SJU - FLT 1013 - EN ROUTE BOS-AUA - UNABLE TO CONTROL COCKPIT OR CABIN TEMPERATURE IN MANUAL OR AUTOMATIC MOD. ALL 3 ZONE TEMPERATURE CONTROL VALVE CIRCUIT BREAKERS POPPED. AIR INTERRUPTED AND LANDED SJU WITHOUT INCIDENT. REPLACED CABIN ZONE TEMPERATURE CONTROLLER PER MM. CLEANED THREE CABIN TEMPERATURE SENSORS. OPERATIONS CHECKED ALL THREE ZONE TEMPERATURES AND FOUND WORKING. RESET ZONE TEMPERATURE CIRCUIT BREAKERS. (M)