What was found
ENROUTE, STATUS MSGS BATTERY CHARGER MAIN AND MAIN BATTERY THEN BATTERY CHARGER MAIN MSG WAS REPLACED BY MAIN BATTERY OVERHEAT MAIN BATTERY WAS NOW CHARGING AT UP TO 67 AMPS BATTERY WAS VISUALLY CHECKED AND FOUND TO BE SMOKING AS PER ALLIANCE TECH CIRCUIT AND BREAKER P320 K-9 PULLED. SWAPPED BATTERY AND CHARGER WITH APU AS PER MM. CHARGING AND BATTERY SERVICE CIRCUIT BEAKER AFTER FIX.