What was found
FOUND CRACK IN FUSELAGE SKIN STATION 138 LONGERON 13L. STOP DRILLED END OF CRACK AND APPLIED NON-PRESSURIZED DOUBLER PATCH PER SRM 53-01-00 FIG 2 SHEET 3, SRM 53-34-00 PAGE 17 FIG 4 SHEET 2, PAGE 16 FIG 4 SHEET 1, SRM 51-01-00 PAGE 1, AND AARD 53-30-00-02 PAGE 1. (M)