As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - FOUND CORROSION ON BEAM RBL 11.06 STATION 798 OUT OF SRM LIMITS. REMOVED CORROSION PER SRM. DYE PENETRANT CHECKED AREA AFTER BLENDING FOR CRACKS, ROTO-PEENED AREA, APPLIED ALODINE AND TWO COATS OF PRIMER. FILLED BLENDED AREA WITH BMS 5-95. (M)