What was found
MCI - FOUND CORROSION ON CARGO FLOOR SUPPORT AT STATION 1155 10 INCHES RBL TOPSIDE AND LOWER SIDE. CORRODED FLOOR SUPPORT WAS REPLACED WITH NEW MPH 5936660-63, PART WAS PRIMED, PAINTED WHITE AND HI-LOCKS WERE INSTALLED PER SRM 51-31-05. (M)