What was found
TUL FEEDER CABLE WIRE NUMBERS 3X1C2A, 3X2C2B, 3X1D2A, 3X2D2B TO R2-41 LEFT AUXILLARY POWER RELAY AT LOWER FORWARD EPC PANEL SHOWS SIGNS OF OVERHEATING. ADEL CLAMP FOR CABLE 3X1C2A SHOWS SIGNS OF BEING OVERHEATED. REPLACED WIRE FEEDER CABLES 3X1C2A, 3X2C2B, 3X1D2A, 3X2D2B TO R2-41 LEFT AUXILLARY POWER RELAY AT LOWER FORWARD EPC PANEL AND REPLACED ONE ADEL CLAMP FOR CABLE 3X1C2A PER MM 24-20-06-2. SYSTEM GROUND CHECKED NORMAL OPERATION.