As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DFW - EMERGENCY LIGHTS AT STATION 1154 INOPERATIVE. FOUND PLASTIC BACK SHELL FOR PLUG FOR BATTERY PACK CONTROL MODULE AB5-4 AT STATION 1154 BROKEN. REPLACED PLASTIC BACK SHELL FOR PLUG FOR EMERGENCY LIGHT BATTERY PACK CONTROL MODULE AB5-4 AT STATION 1154. SYSTEM GROUND CHECKED NORMAL OPERATION.