MEX LEFT FORWARD OVERWING EMERGENCY LIGHTS CAME ON WITH NO POWER. REPLACED SPLICE SP828 CONNECTING WIRES W3142043720 WITH W3142PB AS PER STANDARD WIRING PRACTICE MANUAL. PERFORMED PROXIMITY SWITCH ELECTIC UNIT BITE FOR LEFT FORWARD OVERWING EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. (CLOSED)