What was found
AFW - FLOORBEAM AT STATION 325 AT RBL 86 (VERY OUTBOARD END) BROKEN OFF, AREA IS 1 INCH SQUARE. SMOOTHED AND BLENDED BROKEN EDGE OF CHORD. TWO REPAIR ANGLES MACHINED, EXTRUSION INSTALLED. ANGLES ATTACHED WITH FLUSH HI-LOKS (UPPER FASTENER) AND PROTRUDING HI-LOKS IN LOWER HOLE LOCATIONS. EXISTING FASTENER LOCATIONS REPLACED WITH SAME TYPE AND SIZE AS ORIGINAL.