What was found
FAILSAFE FWD CARGO DOOR CUTOUT ANGLE HAS CORROSION REMOVAL BLENDOUTS ON LOWER SURFACE 2 LOCATIONS AT FASTENERS. DEPTH IS 0.030 INCH BY 0.021 INCH STA 591 & 527.65 SECTION 43 FWD CARGO. PERFORMED HIGH FREQUENCY EDDY CURRENT TO INSURE CRACK FREE. ROTOPEEN BLENDED AREA AND REFINISH THE BLENDED AREA WITH ALODINE AND 2 COATS OF BMS10 11 PRIMER. AFTER INSTALLATION OF FAILSAFE STRAP FABRICATE REPAIR STRAPS FROM 7075T7351 PLATE A MINIMUM OF 0.190 THICK. STRAP EXTENDS A MINIMUM OF .5 INCH BEYOND CENTER AT EACH FASTENER HOLE. FINISHED STRAP WITH ALODINE AND 2 COATS OF BMS10 11 PRIMER AND INSTALLED A STRAP AT EACH BLENDED LOCATION. ADJUST RIP LENGTH OF BOLTS TO ACCOMMODATE REPAIR STRAP.