What was found
AFW - LEFT HAND INBOARD MAIN FLAP LOWER AFT SPAR LOWER SURFACE AT IFS 19 HAD CORROSION. AREA WAS FOUR INCHES BY 1.7 INCHES WITH A DEPTH OF .027 INCH. VERIFY THE CORROSION WAS COMPLETELY REMOVED. ACCOMPLISH EDDY CURRENT INSPECTION ON BLENDED AREA FOR CRACKS. ROTOPEEN BLENDED AREA. REFINISH THE BLENDED AREA WITH ALODINE AND TWO COATS BMS 10 11 PRIMER AND RETURN TO SERVICE WITH NOTED CONDITIONS.