As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DFW - EMERGENCY ESCAPE PATH LIGHT SECTION IN FRONT OF THE LAVATORY INOPERATIVE. FOUND BREAK IN THE POWER FEEDER CABLE TAPE JUST FORWARD OF THE LAVATORY. REPLACED FEED CABLE AT ROW 15 TO LAVATORY FOR EMERGENCY ESCAPE PATH LIGHT SECTION IN FRONT OF THE LAVATORY. SYSTEM GROUND CHECKED NORMAL OPERATION.