MCI - FOUND CORROSION ON STRINGER 39 LEFT AT STATION 454. INSTALLED NEW STRINGER AT 39 LEFT AT STATION 454.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCI - FOUND CORROSION ON STRINGER 39 LEFT AT STATION 454. INSTALLED NEW STRINGER AT 39 LEFT AT STATION 454.