What was found
AFW - KEEL BEAM AT STATION 1219 HAD CORROSION REMOVED FROM THE VERTICAL AND HORIZONTAL FLANGES. REPAIRED PER MRB 767-3237. VERTICAL FLANGE: 0.4 INCH BY 0.9 INCH WITH A DEPTH OF 0.050 INCH. HORIZONTAL FLANGE: 0.8 INCH BY 2.4 INCH WITH A DEPTH OF 0.160 INCH. (S)