What was found
AFW FLOOR BEAM AT STATION 325 HAD CORROSION REMOVAL ON UPPER SURFACE OF HORIZONTAL FLANGES. AREA OF DISCREPANCY IS 2.0 INCH BY 1.5 INCH WITH A DEPTH OF 0.027 INCH AND 0.028 INCH. REPAIRED PER MRB 767 3254.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW FLOOR BEAM AT STATION 325 HAD CORROSION REMOVAL ON UPPER SURFACE OF HORIZONTAL FLANGES. AREA OF DISCREPANCY IS 2.0 INCH BY 1.5 INCH WITH A DEPTH OF 0.027 INCH AND 0.028 INCH. REPAIRED PER MRB 767 3254.