What was found
CORROSION ON ANGLE AFT SIDE OF DOOR JAMB IN AFT CARGO AT STATION 1155 RT LONGERON 27 IS BEYOND LIMITS. AREA OF DISCREPANCY IS 4 INCHES BY 10 INCHES. INSTALLED NEW ANGLE PER SRM 51-01-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON ANGLE AFT SIDE OF DOOR JAMB IN AFT CARGO AT STATION 1155 RT LONGERON 27 IS BEYOND LIMITS. AREA OF DISCREPANCY IS 4 INCHES BY 10 INCHES. INSTALLED NEW ANGLE PER SRM 51-01-00.