What was found
TOP OF FLOOR SUPPORT CORRODED AT STATION 929 AND BUTT LINE 46 RIGHT. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-10-02-0G STATION 929 BUTT LINE 46 RIGHT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TOP OF FLOOR SUPPORT CORRODED AT STATION 929 AND BUTT LINE 46 RIGHT. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-10-02-0G STATION 929 BUTT LINE 46 RIGHT.