What was found
CABIN FLOORBOARD SUPPORT BETWEEN STATION 312 TO 328 HAS CORROSION AROUND NUT PLATE FASTENER HOLE APPROXIMATELY 48 INCHES FROM RIGHT SIDEWALL. CORROSION LEVEL 1. INSTALLED SERVICEABLE FLOORBOARD SUPPORT PER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBOARD SUPPORT BETWEEN STATION 312 TO 328 HAS CORROSION AROUND NUT PLATE FASTENER HOLE APPROXIMATELY 48 INCHES FROM RIGHT SIDEWALL. CORROSION LEVEL 1. INSTALLED SERVICEABLE FLOORBOARD SUPPORT PER SRM 51-40-02.