What was found
AFW - CORROSION FOUND UNDER CARGO FITTING AT STATION 612 FORWARD CARGO DOOR CUTOUT. ADDITIONAL CORROSION FOUND IN TWO HOLES JUST AFT OF STATION 612. REPAIRED IN ACCORDANCE WITH SRM 53-00-015 FIG 101 AND MRB 767-3154.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - CORROSION FOUND UNDER CARGO FITTING AT STATION 612 FORWARD CARGO DOOR CUTOUT. ADDITIONAL CORROSION FOUND IN TWO HOLES JUST AFT OF STATION 612. REPAIRED IN ACCORDANCE WITH SRM 53-00-015 FIG 101 AND MRB 767-3154.