What was found
ONE INCH CRACK IN UPPER J-ANGLE, FORWARD SIDE OF FRAME STATION 1418 AT LONGERON 2 LEFT. FABRICATED AND INSTALLED DOUBLER AT FRAME 1418 AND LONGERON 2 LEFT PER ENGINEERING AUTHORIZATION MD80-53-007990.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ONE INCH CRACK IN UPPER J-ANGLE, FORWARD SIDE OF FRAME STATION 1418 AT LONGERON 2 LEFT. FABRICATED AND INSTALLED DOUBLER AT FRAME 1418 AND LONGERON 2 LEFT PER ENGINEERING AUTHORIZATION MD80-53-007990.