What was found
NUMBER 8 SLAT HAS A BLENDED AREA WITH A BLIND FASTENER INSTALLED IN THE LEADING EDGE SKIN 45 .75 INCHES FROM THE INBOARD END. REMOVED DAMAGED AREA AND INSTALLED FLUSH DOUBLER REPAIR PER AARD 57-43-00-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMBER 8 SLAT HAS A BLENDED AREA WITH A BLIND FASTENER INSTALLED IN THE LEADING EDGE SKIN 45 .75 INCHES FROM THE INBOARD END. REMOVED DAMAGED AREA AND INSTALLED FLUSH DOUBLER REPAIR PER AARD 57-43-00-1.