What was found
FOUND FUSELAGE STATION 500 FRAME INNER CHORD HORIZONTAL FLANGE BENT DOWN BETWEEN STATION 30 LEFT AND 31 LEFT DUE TO SUSPECTED IMPACT FROM A CARGO PALLET. APPROXIMATELY 6 INCHES LONG BY 0.5 INCH WIDE SECTION OF THE FLANGE WAS FOUND BENT DOWN A MAXIMUM OF 0.150 INCH. AS A PERMANENT REPAIR THE FLANGE WAS COLD WORKED BACK TO CONTOUR AND THEN A 0.125 INCH THICK STRAIGHT EXTRUSION WAS FITTED TO THE FORWARD SIDE OF THE FRAME ALONG THE DAMAGED AREA UNDER ENGINEERING AUTHORIZATION B767-53-007916.